TM 9-2350-277-20-6
REPAIR CHEMICAL ALARM JUNCTION BOX (M113A3 ONLY) Continued
0920 00
INSTALLATION
1.
Install wiring harness (15) in junction box (6) with four washers (13), screws (12) and new locknuts (14).
2.
Install circuit breaker (3) in junction box (6) with two screws (4) and new locknuts (5).
3.
Install lead (2) on circuit breaker (3) with screw (1).
4.
Install terminal board (9) in junction box (6) with screw (10) and new locknut (11).
5.
Install three leads (8) on terminal board (9) with three screws (7).
6.
Install new grommet (16).
FOLLOW-THROUGH STEPS
1.
Install junction box (WP 0919 00).
END OF TASK
0920 00-3/4 blank