TM 9-2350-277-20-6INSTALL/REMOVE CHEMICAL AGENT AUTOMATIC ALARM KIT (M113A3 ONLY) —Continued0918 00REMOVAL1. Disconnect power cable (1) plug 6B POS (2) from battery power lead socket (3).2. Remove screw (4), lockwasher (5), clamp (6) with cable (7), power cable (1) ground lead (8), two ground leads (9),capacitor bracket (10), and lockwasher (11) from weldnut (12). Discard lockwashers.3. On weldnut (12), install new lockwasher (11), capacitor bracket (10), two ground leads (9), clamp (6) with cable (7), newlockwasher (5), and screw (4).0918 00-8