TM 9-2350-277-20-6INSTALL/REMOVE CHEMICAL AGENT AUTOMATIC ALARM KIT (M113A3 ONLY) —Continued0918 0024. Remove screw (8), lockwasher (9), clamp (10) with cable (11), two ground leads (12), capacitor bracket (13), andlockwasher (14) from weldnut (15). Discard lockwashers.25. On weldnut (15), install new lockwasher (14), capacitor bracket (13), two ground leads (12), power cable (1), groundlead (16), clamp (10) with cable (11), new lockwasher (9), and screw (8).26. Connect power cable (1) plug 6B POS (17) to battery power lead socket (18).27. Connect battery ground strap (WP 0337 00). Be sure that no grounds or shorts exist see TM 3-6665-273-20.0918 00-7