TM 9-2350-277-20-6
REPLACE STE/ICE ENGINE WIRING HARNESS Continued
0882 00
3.
Connect lead (5) to fuel return pressure switch (6).
4.
Connect lead (7) to turbo outlet pressure switch (8).
CAUTION
Excess heat can cause fuel return pressure switch to leak. Leaking fuel can catch fire and cause
equipment damage. Make sure electrical lead is secured away from exhaust duct.
5.
Secure lead (5) to lead (9) with new tie strap (10).
6.
Install leads (11) on starter solenoid (12) terminal. Secure with two nuts (13) and new lockwashers (14).
7.
Install leads (15) on starter (16) terminals. Secure with nut (17) and new lockwasher (18).
0882 00-6