TM 9-2350-277-20-6REPLACE STE/ICE CREW WIRING HARNESS (M577A3 AND M1068A3 ONLY) —Continued0879 007. Disconnect plug (10) from connector (11) in power plant compartment.8. Remove four locknuts (12), screws (13), washers (14), and connector (15) from bulkhead. Have helper assist. Discardlocknuts.9. Unplug wiring harness (16) from STE/ICE distribution box (17). Remove harness.INSPECTION-ACCEPTANCE AND REJECTION CRITERIA1. Check leads for continuity. Use multimeter.2. Check connectors.REPAIR OR REPLACEMENT1. Replace bad leads.2. Replace cracked or broken connectors (WP 0382 00).0879 00-4