TM-9-2350-277-20-6 Carrier Personnel Full Tracked Armored M113A3 2350-01-219-7577 (EIC AE7) Carrier Command Post Light Tracked M577A3 2350-01-369-6085 (EIC AE7) Manual
Page Navigation
221
222
223
224
225
226
227
228
229
230
231
TM 9-2350-277-20-6
REPLACE STE/ICE CREW WIRING HARNESS (M113A3, M901A3, AND M1059A3 ONLY)
— Continued
0878 00
3.
Disconnect plug (6) from connector (7) in power plant compartment.
4.
Remove four locknuts (8), washers (9), screws (10), and connector (7) from bulkhead (11). Discard locknuts. Have
helper assist.
5.
Unplug wiring harness (5) from STE/ICE distribution box (12). Remove harness.