TM 9-2350-277-20-6REPLACE CABLE W45 (M1068A3 ONLY) — Continued 0853 00INSTALLATION1. Position cable W45 (1) in carrier. Connect cable plug W45P13 (2) into power control enclosure jack A1J33 (3).2. Connect cable plug W45P1 (4) into DC power extension box jack A9J2 (5).3. Connect cables with screw (6) and clamps (7) to bulkhead.4. Secure cables with three screws (8) and clamps (9) to bulkhead.5. Secure remaining cable W45 with six new straps (10) evenly between clamps (9).FOLLOW-THROUGH STEPS1. Connect battery ground lead (WP 0853 00).END OF TASK0853 00-3/4 blank