TM 9-2350-277-20-6
REPLACE CABLE W45 (M1068A3 ONLY) Continued
0853 00
INSTALLATION
1.
Position cable W45 (1) in carrier. Connect cable plug W45P13 (2) into power control enclosure jack A1J33 (3).
2.
Connect cable plug W45P1 (4) into DC power extension box jack A9J2 (5).
3.
Connect cables with screw (6) and clamps (7) to bulkhead.
4.
Secure cables with three screws (8) and clamps (9) to bulkhead.
5.
Secure remaining cable W45 with six new straps (10) evenly between clamps (9).
FOLLOW-THROUGH STEPS
1.
Connect battery ground lead (WP 0853 00).
END OF TASK
0853 00-3/4 blank