TM 9-2350-277-20-6
REPLACE CABLE W38, CABLE W29, AND CABLE ADAPTER (M1068A3 ONLY)
Continued
0850 00
INSTALLATION
1.
Install dummy connector plug (1) in connector adapter plug T2P3 (2).
2.
Connect cable plug W29P2 (3) to cable plug W38P6 (4).
3.
Connect cable plug W29P1 (5) to connector adapter plug T2P2 (6).
4.
Connect cable plug W38P7 (7) to power control enclosure jack A1J28 (8).
5.
Secure cables with new strap (9).
6.
Connect connector adapter plug T2P1 (10) to circuit 415 lead (11).
FOLLOW-THROUGH STEPS
1.
Connect battery ground lead (WP 0338 00).
END OF TASK
0850 00-3/4 blank