TM 9-2350-277-20-4REMOVE/INSTALL FAN DRIVE PULLEY ACCESS COVER 0440 00THIS WORK PACKAGE COVERS:Removal (page 0440 00-1).Installation (page 0440 00-2).INITIAL SETUP:Maintenance LevelUnitTools and Special ToolsGeneral Mechanic’s Tool Kit (WP 0926 00, Item 65)Materials/PartsLockwasher (4)Personnel RequiredUnit MechanicReferencessee your -10Equipment ConditionEngine stopped (see your -10)Carrier blocked (see your -10)Power plant upper rear access panelremoved (see your -10)REMOVAL1. Remove four screws (1), lockwashers (2), washers (3), and fan pulley access cover (4) from power plant compartmentrear bulkhead. Discard lockwashers.0440 00-1