6.
Install new grommet (1) on ground lead (2). Route ground lead into master switch panel assembly (3) and secure
grommet.
7.
Install ground lead (2) on negative post (4) of auxiliary power receptacle (5). Secure with screw (6) and new
lockwasher (7).
0260 00-5