TM 9-2350-277-20-3
REPLACE MASTER SWITCH PANEL ASSEMBLY (M113A3, M901A3, M1059A3, M1064A3,
AND M58 ONLY) Continued
0260 00
INSTALLATION
1.
Install new grommet (18) on circuit 49 lead (15). Route lead into distribution box (17) and secure grommet.
2.
Install circuit 49 lead (15) on bus bar (16). Secure with new lockwasher (14) and screw (13).
3.
Install new grommet (7) on circuit 6 lead (5). Route lead into master switch panel assembly (8) and secure grommet.
4.
Install circuit 6 lead (5), circuit 2 lead (3), and circuit 400 lead (4) on conductor bus (6). Secure with screw (1) and new
locknut (2).
5.
Install circuit 2A lead (11) on master switch post (12). Secure with new lockwasher (10) and nut (9).
0260 00-4