TM 9-2350-277-20-3
REPLACE GOVERNOR ASSEMBLY Continued
0397 00
INSTALLATION
1.
Install new governor assembly (5) in transmission. Twist governor slightly to the right while inserting it into bore inside
transmission.
2.
Install cover (3) and new gasket (4) on transmission. Secure with four washers (2) and new self-locking bolts (1).
TIGHTEN BOLTS TO 13-15 LB-FT (18-20 N m) TORQUE.
FOLLOW-THROUGH STEPS
1.
Install power plant (WP 0156 00).
2.
Close power plant door (see your -10).
3.
Raise trim vane (see your -10).
END OF TASK
0397 00-3/4 blank