TM 9-2350-277-20-3DISCONNECT/CONNECT BATTERY GROUND LEAD (M981A3 ONLY) 0339 00THIS WORK PACKAGE COVERS:Disconnect (page 0339 00-1).Connect (page 0339 00-3).INITIAL SETUP:Maintenance LevelUnitTools and Special ToolsGeneral Mechanic’s Tool Kit (WP 0926 00, Item 65)Personnel RequiredUnit MechanicReferencesSee your -10Equipment ConditionEngine stopped (see your -10)Carrier blocked (see your -10)Ramp lowered (see your -10)VEHICLE BAT, EQPT BAT, and EMERGENCYswitches set to OFF (see your -10)Battery access cover removed (see your -10)REMOVALDISCONNECTWARNINGBattery posts and cables touched by metal objects can short circuit, and burn you or injure you.Use caution when working with tools or other metal objects. Do not wear jewelry when workingon electrical systems. Keep tools away from posts, wires, and terminals.WARNINGGas from batteries can explode and injure you. Do not allow sparks near batteries. Battery acidcan blind or burn you. Do not get acid on your skin or into your eyes.0339 00-1
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business