TM 9-2350-277-20-3
REPLACE DISTRIBUTION BOX ASSEMBLY (M901A3 ONLY) Continued
0272 00
10. Install two grommets (1) and (2), cable assembly W8 lead (3), and circuit 49 lead (4). Install circuit 49 lead (5) and cable
assembly W8 leads (6) and (7) on bus bar (8). Secure with new lockwasher (9) and screw (10).
11. Install grommet (11) and circuit 10, 15, 27E lead (12) in distribution box (13). Install circuit 10, 15, 27E lead (14) and
circuit 450A lead (15) on bus bar (8). Secure with new lockwasher (16) and screw (17).
12. Install two grommets (18) circuit 6 lead (19), and circuit 6A lead (20) in distribution box (13). Install circuit 6 lead,
circuit 6A lead, and cable assembly W8 leads (21) on bus bar (8). Secure with new lockwasher (22) and screw (23).
0272 00-5