Do Step 10 and Step 11 for M113A3 carriers with water/ration heater kit installed only.
10. Connect lead 222A (1) to water/ration heater circuit breaker (2).
11. Install lead 222A (1) on bus bar (3) in distribution box (4).
12. Secure circuit lead 450C (5) to bus bar (3) in distribution box (4) with screw (6) and new lockwasher (7).
13. Install grommet (8) on circuit lead 2 (9) and grommet (10) on lead 2A (11). Route leads into distribution box (4) and
install grommets in distribution box.
14. Install grommet (12) on circuit 27E, 10, and 15 lead (13). Route lead into distribution box (4) and install grommet in
distribution box.
15. Secure circuit 27E, 10, and 15 lead (13) and lead 450A (14) to bus bar (3) with screw (15) and new lockwasher (16).
NOTE
Do Step 16 and Step 17 for M113A3 carriers with water/ration heater kit installed only.
16. Install grommet (17) on circuit lead 222B (18). Route lead into distribution box (4) and install grommet in distribution
box.
17. Connect circuit lead 222B (18) to water/ ration circuit breaker (2) in distribution box (4).