TM 9-2350-277-20-2
REPLACE FUEL SUPPLY HOSES, TUBES AND FITTINGS (M577A3 AND M1068A3 ONLY)
Continued
0193 00
23. Install leads (7), two elbows (5), and two tubes (3) and (6) on four weldnuts (11). Secure with four clamps (12), new
lockwashers (13), and screws (14).
24. Connect personnel heater fuel hose (15) to shutoff valve (1).
FOLLOW-THROUGH STEPS
1.
Fill fuel tank (see your -10).
2.
Connect battery ground lead (WP 0338 00).
3.
Start engine (see your -10). Check for leaks.
4.
Stop engine (see your -10).
5.
Install power plant rear access panel (WP 0439 00).
6.
Install rear compartment floor plates (WP 0539 00) or (WP 0544 00).
7.
Start engine (see your -10).
8.
Raise and lock ramp (see your -10).
9.
Stop engine (see your -10).
END OF TASK
0193 00-8