TM 9-2350-277-20-2REPAIR AIR CLEANER RETAINER 0170 00THIS WORK PACKAGE COVERS:Removal (page 0170 00-1).Installation (page 0170 00-1).INITIAL SETUP:Maintenance LevelUnitTools and Special ToolsGeneral Mechanic’s Tool Kit (WP 0926 00, Item 65)Materials/PartsLockwasher (8)Personnel RequiredUnit MechanicReferencesSee your -10Equipment ConditionEngine stopped (see your -10)Carrier blocked (see your -10)Trim vane lowered (see your -10)Power plant front access door open (see your -10)Air cleaner door removed (see your -10)REMOVAL1. Release retainer handle (1) and slide out filter element (2).2. Remove eight nuts (3), lockwashers (4), and screws (5) from retainer (6) and housing (7). Remove retainer fromhousing. Discard lockwashers.INSTALLATION1. Position new retainer (6) into housing (7). Secure with eight screws (5), new lockwashers (4), and nuts (3). Tighten allnuts at this time.NOTECheck operation of retainer to make sure there is no binding during operation. If bindingoccurs, loosen screws and repeat Step 1.2. Install filter element (2) and reset retainer handle (1).0170 00-1