TM 9-2350-277-20-2
REPAIR AIR CLEANER RETAINER
0170 00
THIS WORK PACKAGE COVERS:
Removal (page 0170 00-1).
Installation (page 0170 00-1).
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanics Tool Kit (WP 0926 00, Item 65)
Materials/Parts
Lockwasher (8)
Personnel Required
Unit Mechanic
References
See your -10
Equipment Condition
Engine stopped (see your -10)
Carrier blocked (see your -10)
Trim vane lowered (see your -10)
Power plant front access door open (see your -10)
Air cleaner door removed (see your -10)
REMOVAL
1.
Release retainer handle (1) and slide out filter element (2).
2.
Remove eight nuts (3), lockwashers (4), and screws (5) from retainer (6) and housing (7). Remove retainer from
housing. Discard lockwashers.
INSTALLATION
1.
Position new retainer (6) into housing (7). Secure with eight screws (5), new lockwashers (4), and nuts (3). Tighten all
nuts at this time.
NOTE
Check operation of retainer to make sure there is no binding during operation. If binding
occurs, loosen screws and repeat Step 1.
2.
Install filter element (2) and reset retainer handle (1).
0170 00-1