TM 9-2350-277-20-2
REPAIR AIR CLEANER ASSEMBLY Continued
0169 00
INSTALLATION
NOTE
Clean area on door before installing new gasket.
1.
Apply adhesive to new gasket (3).
2.
Install new gasket (3) on door (1).
3.
Install door (1) on air cleaner (2).
FOLLOW-THROUGH STEPS
1.
Close power plant front access door (see your -10).
2.
Raise trim vane (see your 10).
END OF TASK
0169 00-2