TM 9-2350-277-20-2
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING
LUBRICATION INSTRUCTIONS Continued
0155 00
ITEM
NO.
INTERVAL
MAN-
HOUR
ITEM TO BE
CHECKED OR
SERVICED
CREWMEMBER
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE
IF:
NOTE
Additional data on chemical Agent
Automatic Alarm Lit for the M113 FOV
can be found in:
Operators and Unit Manual TM
3-6665-224-12
Repair Parts and Special Tools List TM
9-2350-277-24P
d. Check mounting screws on junction box.
Tighten loose screws in junction box. Tighten
loose screws to 72 lb-in (8 N m) torque. Use
torque wrench (WP 0926 00, Item 79) and
socket set (WP 0926 00, Item 72).
e. Check grommet. Replace cracked or worn
grommet.
f. Check cable and circuit breaker terminal.
Tighten loose connections. Replace damaged
terminals.
g. Check cables. Replace frayed or cracked cables
(WP 0919 00).
0155 00-149