TM 9-2350-277-20-2PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDINGLUBRICATION INSTRUCTIONS — Continued0155 00ITEMNO.INTERVALMAN-HOURITEM TO BECHECKED ORSERVICEDCREWMEMBERPROCEDUREEQUIPMENTNOT READY/AVAILABLEIF:38Semi-AnnualPower plantGrill and PowerPlant FrontAccess Doora. Check screws on power plant grill for looseness.Tighten loose screws to 100-120 lb-ft (136–163N m) torque. Use torque wrench (WP 0926 00,Item 79).Damageprevents doorfrom closing,sealing andlocking.WARNINGPower plant door may spring open. Whenopening door, stay out of door path.Soldiers can be injured.b. Check power plant front access door seal forcracks, cuts, stiffness, and looseness. If seal isloose, tighten. If seal is damaged, replace(WP 0472 00).0155 00-87