TM 9-2350-277-20-2
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING
LUBRICATION INSTRUCTIONS Continued
0155 00
ITEM
NO.
INTERVAL
MAN-
HOUR
ITEM TO BE
CHECKED OR
SERVICED
CREWMEMBER
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE
IF:
38
Semi-
Annual
Power plant
Grill and Power
Plant Front
Access Door
a. Check screws on power plant grill for looseness.
Tighten loose screws to 100-120 lb-ft (136163
N m) torque. Use torque wrench (WP 0926 00,
Item 79).
Damage
prevents door
from closing,
sealing and
locking.
WARNING
Power plant door may spring open. When
opening door, stay out of door path.
Soldiers can be injured.
b. Check power plant front access door seal for
cracks, cuts, stiffness, and looseness. If seal is
loose, tighten. If seal is damaged, replace
(WP 0472 00).
0155 00-87