TM 9-2350-277-20-1STE/ICE TEST 84 GENERATOR NEGATIVE CABLE VOLTAGE DROP DIAGNOSTICTROUBLESHOOTING—Continued0153 00BY1. Remove plug W1P2 (1) from STE/ICE distribution box jack J2(2).2. Measure resistance between STE/ICE distribution box jack J2 (2),pins W (3) and P (4).3. Does VTM read more than one ohm?YESNOBYN1. Faulty W1 cable. Beyond unitmaintenance repair.2. Notify supervisor.B2Y1. Remove harness 12354593 plug P1 (1) from STE/ICEdistribution box jack J1 (2).2. Measure resistance between harness 12354593 plug P1 (1), pins k(3) and e (4). Use VTM.3. Does VTM read more than one ohm?YESNOB2YN1. Replace STE/ICE distribution box(WP 0874 00) thru (WP 0877 00).2. Verify no faults found.0153 00-3