STE/ICE TEST 83
GENERATOR
FIELD VOLTAGE DIAGNOSTIC
TROUBLESHOOTING—Continued
0152 00
C3Y
1. Remove harness 12354672 plug P4 (1) from harness 12354593
jack J1 (2).
2. Measure
resistance
between harness 12354672 plug P4 (1), pins
l
(3) and E (4). VTM should read 0 ohms.
3. Does VTM indicate a fault?
YES
NO
C3YN
1. Replace harness 12354593
(WP 0882 00).
2. Verify no faults found.
C4Y
1. Replace harness 12354672 (WP 0882 00).
2. Verify no faults found.