TM 9-2350-277-20-1
IN BLACKOUT MODE, FLUORESCENT LIGHTS OPERATE INCORRECTLY (M1068A3
ONLY)Continued
0101 00
A6Y
1. Install cable W35 plug P1 (1) on adapter plug P2 (2).
2. Install W35 plug P9 (3) on jack 29 (4) of Power Control
Enclosure.
3. Measure resistance between relay XK5 (5), pin X2 (6), and relay
XK3 (7), pin X2 (8).
4. Does multimeter read 0 ohms?
YES
NO
A6YN
1. Faulty lead 3F of XK2. Beyond unit
maintenance repair.
2. Notify Supervisor.
0101 00-6