TM 9-2350-277-20-1
IN BLACKOUT MODE, FLUORESCENT LIGHTS OPERATE INCORRECTLY (M1068A3
ONLY)Continued
0101 00
A3Y
1. Set MASTER SWITCH to OFF.
2. Remove cable W35, plug P1 (1) from adapter plug P2 (2).
3. Measure resistance between plugs P1 (3), P2 (2), and P3 (4) of
adapter.
4. Does multimeter read 0 ohms for each measurement?
YES
NO
A3YN
1. Replace adapter (WP 0849 00).
2. Verify no faults found.
A4Y
1. Remove cable W35 plug P9 (1) from jack J29 (2) of Power
Control Enclosure.
2. Measure resistance between plugs P1 (3) and P9 (1) of cable
W35.
3. Does multimeter read 0 ohms?
YES
NO
A4YN
1. Replace cable W35 (WP 0849 00).
2. Verify no faults found.
0101 00-4