IN BLACKOUT MODE, FLUORESCENT LIGHTS OPERATE INCORRECTLY (M1068A3 ONLY)Continued - TM-9-2350-277-20-1_489
IN BLACKOUT MODE, FLUORESCENT LIGHTS OPERATE INCORRECTLY (M1068A3 ONLY)Continued - TM-9-2350-277-20-1_491
TM-9-2350-277-20-1 Hull Powerpack Drive Controls Tracks Suspension and Associated Components Carrier Ammunition Tracked Manual
Page Navigation
373
374
375
376
377
378
379
380
381
382
383
TM 9-2350-277-20-1
IN BLACKOUT MODE, FLUORESCENT LIGHTS OPERATE INCORRECTLY (M1068A3
ONLY)—Continued
0101 00
A3Y
1. Set MASTER SWITCH to OFF.
2. Remove cable W35, plug P1 (1) from adapter plug P2 (2).
3. Measure
resistance
between plugs P1 (3), P2 (2), and P3 (4) of
adapter.
4. Does
multimeter
read 0 ohms for each measurement?
YES
NO
A3YN
1. Replace adapter (WP 0849 00).
2. Verify no faults found.
A4Y
1. Remove cable W35 plug P9 (1) from jack J29 (2) of Power
Control Enclosure.
2. Measure
resistance
between plugs P1 (3) and P9 (1) of cable
W35.
3. Does
multimeter
read 0 ohms?
YES
NO
A4YN
1. Replace cable W35 (WP 0849 00).
2. Verify no faults found.
0101 00-4
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business