TM 9-2350-277-20-1PERSONNEL HEATER MALFUNCTIONS 0086 00INITIAL SETUP:Maintenance LevelUnitTools and Special ToolsGeneral Mechanic’s Tool Kit (WP 0926 00, Item 65)Multimeter (WP 0926 00, Item 30)Electrical Connector Pliers (WP 0926 00, Item 31)Personnel RequiredUnit MechanicReferencesSee your -10TM 9-2540-205-24&PEquipment ConditionEngine stopped (see your -10)Carrier blocked (see your -10)Trim vane lowered (see your -10)Power plant access door open (see your -10)Ramp lowered (see your -10)Drivers power plant access panel removed (see your -10)Power plant rear access panel removed (see your -10)Heater on LOW (see your -10)Rear floor plates removed (WP 0539 00) thru(WP 0545 00)T1. Turn MASTER SWITCH to ON (see your -10).2. Depress HEATER ON indicator cover lens (see your -10).3. Does indicator light come on?YESNOGO TO BY (PAGE 0086 00-4)Y1. Release HEATER ON indicator.2. Move HEATER SWITCH to START.3. Does heater blower come on?YESNOGO TO CY (PAGE 0086 00-6)2Y1. Does heater fuel pump come on?YESNOGO TO EY (PAGE 0086 00-8)3Y1. Does HEATER ON indicator come on in less than 3 minutes?YESNOGO TO GY (PAGE 0086 00-9)0086 00-1