TM 9-2350-277-20-1RAMP WILL NOT RAISE OR FREE FALLS 0084 00INITIAL SETUP:Maintenance LevelUnitTools and Special ToolsGeneral Mechanic’s Tool Kit (WP 0926 00, Item 65)Personnel RequiredUnit MechanicReferencesSee your -10Equipment ConditionEngine stopped (see your -10)Carrier blocked (see your -10)Ramp lowered (see your -10)Trim vane lowered (see your -10)Power plant access door opened (see your -10)Driver’s power plant access panel removed(WP 0441 00)Power plant rear access panels removed (WP 0439 00)Rear floor plates removed (WP 0539 00) thru(WP 0545 00)WARNINGLowering ramp could injure personnel. Make sure no one is in ramp zone before you lowerramp. If tactical situation permits, sound horn before dropping ramp.T1. Check ramp hydraulic fluid level in sight-glass (See your -10).2. Is fluid level correct?YESNOGO TO AY (PAGE 0084 00-3)0084 00-1