TM 9-2350-277-20-1
RAMP WILL NOT RAISE OR FREE FALLS
0084 00
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanics Tool Kit (WP 0926 00, Item 65)
Personnel Required
Unit Mechanic
References
See your -10
Equipment Condition
Engine stopped (see your -10)
Carrier blocked (see your -10)
Ramp lowered (see your -10)
Trim vane lowered (see your -10)
Power plant access door opened (see your -10)
Drivers power plant access panel removed
(WP 0441 00)
Power plant rear access panels removed (WP 0439 00)
Rear floor plates removed (WP 0539 00) thru
(WP 0545 00)
WARNING
Lowering ramp could injure personnel. Make sure no one is in ramp zone before you lower
ramp. If tactical situation permits, sound horn before dropping ramp.
T
1. Check ramp hydraulic fluid level in sight-glass (See your -10).
2. Is fluid level correct?
YES
NO
GO TO AY (PAGE 0084 00-3)
0084 00-1