TM 9-2350-277-20-1FRONT AND/OR REAR BILGE PUMP(S) AND/OR LIGHTS DON’T WORK—Continued 0080 00B2Y1. Measure voltage between bulb socket center contact (1) andground.2. Does multimeter read less than 17 volts?YESNOB2YN1. Replace BILGE PUMP ON lightassembly (WP 0286 00).2. Verify no faults found.B3Y1. Turn MASTER SWITCH to OFF.2. Install plug 451 B or 452 B on indicator light assembly.3. Remove master switch panel from distribution box (WP 0260 00or WP 0261 00).4. Remove plug 450 B (1) and plug 450 C (2) from front bilge pumpcircuit breaker (3); or remove plug 450 (4) and plug 450 A (5)from rear bilge pump circuit breaker (6).5. Check continuity across circuit breaker jacks.6. Is there continuity?YESNOB3YN1. Replace bilge pump circuit breaker(WP 0275 00).2. Verify no faults found.0080 00-3