2-6
Change 4
TM 9-2360-267-34
TRANSMISSION
OVERHEATS
Check oil cooler core (TM 9-2520-234-35). Repair or replace oil cooler core.
AIR CLEANER DUST BLOWER MOTORS
DO NOT OPERATE
1 Repair blower motor (p 4-30).
2 Check impeller housing for clogging (p 4-30).
WARNING
Use low pressure air and wear approved eye protection.
3 Check for damaged impeller (p 4-31).
Replace impeller if damaged.