6-42TM 9-2350-267-20BATTERIES: BATTERY SPECIFIC GRAVITY CHECK, REMOVAL AND INSTALLATIONSPECIFIC GRAVITY CHECKWARNINGSet MASTER switch OFF. When working onbatteries,wear eye protection, remove alljewelry, dog tags and metal items.CAUTIONWhen removing batteries always disconnectground cables first.ASwing plastic cover (1) back on duo-check coolant and bat-tery tester. Clean measuring surface (2) and bottom cover(3) with clean soft cloth (item 16, Appx D).BRemove battery caps (4) from all cells.NOTERepeat steps B through D for each cell.CUse black dipstick (5) to obtain small sample of battery acid.DPlace few drops of acid onto measuring surface (2) throughopening in cover plate.TA311073