RECTIFIER: REMOVAL AND INSTALLATION
REMOVAL
WARNING
Turn OFF MASTER switch. Disconnect battery
ground cable.
A Disconnect wiring harnesses (1 and 2).
B
Remove four screws (3) and four flat washers (4).
C
Remove two brass screws (5) and two lockwashers (6).
D
Remove rectifier (7).
E
Scrape packing from groove of rectifier base.
INSTALLATION
A
B
C
D
Coat packing groove with silicone compound (item 58,
Appx D), and fill groove with packing.
Install rectifier (7) and secure with two brass screws (5) and
two lockwashers (6). Torque screws to 16 lb-ft.
Install four flat washers (4) and screws (3). Torque to 30 lb-ft.
Connect wiring harnesses (1 and 2).
TA311038
6-7
TM 9-2350-267-20