6-2
TM 9-2350-267-20
Section I POWERPACK ELECTRICAL SYSTEM
GENERAL INSPECTION AND REPAIR PROCEDURES
The technician will conduct a visual inspection of electrical components and
wiring harnesses during removal and disassembly to determine serviceability or
repair/replace status of the items. During inspection, look for the following
conditions and take actions as indicated
l Cracked tom or deteriorated wire/cable insulation.
Replace or repair individual harness leads where practical.
Replace entire harness if necessary.
l Burned or discolored connectors or components.
Troubleshoot electrical circuitry to correct problem. Repair or replace
components, circuit leads, harnesses and connectors as necessary.
l Cracked, broken or damaged electrical component housings.
Repair where practical. If necessary, replace components such as
master relay, generator, rectifier, voltage regulator and solenoids.
l Broken, crocked or damaged connectors (i.e., missing pins).
Repair where practical. Replace connector if necessary.
TA311033