SURGE TANK: REMOVAL AND INSTALLATION (CONTINUED)
REMOVAL
A
Remove two screws (1), two lockwashers (2) and retainer (3).
Discard lockwashers.
B
Loosen clamp (4) at elbow (5).
1
C
Loosen two clamps (6 and 7).
D Unscrew two nuts (8 and 9).
(
E
Disconnect five hoses (10, 11, 12, 13 and 14) from surge tank
(15).
F
Lift surge tank (15) up and out.
(
NOTE
(
.
Only remove pads that are defective and need to
H Use dry-cleaning solvent (item 19, Appx D), wire brush
be replaced.
(item 48, Appx B) and rags to clean pad-mounting surface
G Use putty knife to pry and scrape hull-mounted pads (16) from
thoroughly. Remove all residue from old pad and adhesives.
hull.
WARNING
Dry-cleaning solvent (PD-680) is toxic and flam-
mable. To prevent personal injury when using
PD-680, use only in a well ventilated area. Avoid
breathing vapors. If you become dizzy get fresh
air immediately and seek medical attention. Avoid
contact with eyes, skin and clothing. Use protec-
tive goggles, gloves, and clothing. If contact is
made, immediately flush with water and seek
medical attention. The flashpoint for Type I dry-
cleaning solvent is 1000 F (38 C); for Type II it is
1380 F (50 C). Do not use near open flame or ex-
cessive heat.
5-16.3
Change 1
TA312774
TM 9-2350-267-20