SURGE TANK: REMOVAL AND INSTALLATION (CONTINUED)REMOVALARemove two screws (1), two lockwashers (2) and retainer (3).Discard lockwashers.BLoosen clamp (4) at elbow (5).1CLoosen two clamps (6 and 7).D Unscrew two nuts (8 and 9).(EDisconnect five hoses (10, 11, 12, 13 and 14) from surge tank(15).FLift surge tank (15) up and out.(NOTE(.Only remove pads that are defective and need toH Use dry-cleaning solvent (item 19, Appx D), wire brushbe replaced.(item 48, Appx B) and rags to clean pad-mounting surfaceG Use putty knife to pry and scrape hull-mounted pads (16) fromthoroughly. Remove all residue from old pad and adhesives.hull.WARNINGDry-cleaning solvent (PD-680) is toxic and flam-mable. To prevent personal injury when usingPD-680, use only in a well ventilated area. Avoidbreathing vapors. If you become dizzy get freshair immediately and seek medical attention. Avoidcontact with eyes, skin and clothing. Use protec-tive goggles, gloves, and clothing. If contact ismade, immediately flush with water and seekmedical attention. The flashpoint for Type I dry-cleaning solvent is 1000 F (38 ‘C); for Type II it is1380F (50 “C). Do not use near open flame or ex-cessive heat.5-16.3Change 1TA312774TM 9-2350-267-20