YzAAABACDisconnect wiring harness 12351500 or 12352354 connector P7 frombracket-mounted connector of wiring harness 12351461.Place red lead of multimeter in socket E of wiring harness 12351461 andblack lead of multimeter in socket C.Turn MASTER switch ON (TM 9-2350-267-10).Check for 24 ± 3 vdc.Turn MASTER switch OFF (TM 9-2350-267-10). If voltage is indi-cated repair wire 10 or replace wiring harness 12351500 or 12352354(p 14-50.5). Verify problem is solved. If no voltage is indicated, connectwiring harness 12351500 or 12352354 connector P7 to bracket-mountedconnector of wiring harness 12351461 and go to step AD.AD Disconnect wiring harness 12351461, wire 10, from circuit breaker No.3 on circuit breaker panel No. 2.AE Place red lead of multimeter in circuit breaker socket and ground blacklead of multimeter.AF Turn MASTER switch On (TM 9-2350-267-10).AG Check for 24 ± 3 vdc.AH Turn MASTER switch OFF (TM 9-2350-267-10). If voltage is indi-cated, repair wire 10 or replace wiring harness 12351461(p 14-50.5). Verify problem is solved. If no voltage is indicated, replacecircuit breaker (p 6-54). Verify problem is solved.2-287Change 4TM 9-2350-267-20