2-194
Change 4
TM 9-2350-267-20
G Place red multimeter lead on bilge pump circuit breaker output (wire
452B) and ground black lead. If voltage is present, repair or replace wire
452B (p 6-72). If no voltage, go to step H.
H Place red multimeter lead on bilge pump circuit breaker input (wire
452A) and ground black lead. If voltage is present replace circuit
breaker (p 6-54). If no voltage, repair or replace wire 452A (Appx F).