P
Turn MASTER switch OFF. Check voltage. Place red probe
of multimeter on terminal C2 of AFES relay no. 2. Ground black
probe. Turn MASTER switch ON. If no voltage is indicated,
replace electrical harness 12351461 (p 6-93). If voltage is in-
dicated, check voltage at terminal Xl of relay no. 2. If voltage
is not indicated, replace harness 12351461 (p 6-93). If voltage
is indicated, check voltage at terminal C1 of relay no. 2. If
voltage is not indicated, replace AFES relay no. 2 (p 14-36). If
voltage is indicated, go to step Q.
Q Turn MASTER switch OFF. Disconnect wires from terminals
11 and 12 of AFES relay no. 2. Turn MASTER switch ON.
Check continuity between terminals 11 and 12 of AFES relay
no. 2. If continuity is not indicated, replace AFES relay no. 2
(p 14-36). If continuity is indicated, turn MASTER switch OFF,
reconnect wires to terminals 11 and 12 of relay no. 2, and go
to step R.
TA310546
2-187