A Disconnect wire 27 from MASTER WARNING light. Thenturn MASTER switch ON. Using multimeter set on dc voltsscale, place red lead in wire 27 and ground black lead to hull.If voltage is present, go to step B. If no voltage, repair or replacewire 27 (p 6-84).BDisconnect wire 509 from MASTER WARNING light. Withred multimeter lead in wire 27, place black lead in wire 509. Ifvoltage is present, replace bulb (p 7-53). If no voltage, repairwire 509 (p 6-84).TA3104662-107TM 9-2350-267-20