COMPARTMENT HYDRAULIC HOSES AND ASSOCIATED CONNECTING PARTS: REMOVAL AND INSTALLATION (CONTINUED)CAUTIONHydraulic lines and ports should be capped afterdisconnecting lines to avoid entry of contaminantsinto system.FRemove nipple (9) from elbow (10).WARNINGG Remove elbow (10) from adapter (11).Make sure all systems are shut down andMASTER switch is OFF. Hydraulic fluid maybeH Remove preformed packing (12). Discard packing.HOT.IDisconnect hose (13) from APU bulkhead nipple (14) andadapter (15).INSTALLATIONAApply pipe sealant (item 57, Appx D) to all male pipe threads.BConnect hose (13) to APU bulkhead nipple (14) and adapter (15).REMOVALcInstall new preformed packing (12).D Install elbow (10) on adapter (11).A Disconnect hose (1) from pressure switch (2) and elbow (3).EInstall nipple (9) on elbow (10).BDisconnect hose (4) from elbow (5) and adapter (6).FInstall elbow (8) on nipple (9).C Remove elbow (5) from APU wall coupling.G Install adapter (6) on valve (7).D Remove adapter (6) from valve (7).H Install elbow (5) in APU wall coupling.NOTEIConnect hose (4) to elbow (5) and adapter (6).APU must be removed to perform steps E throughI (see p 13-1).JConnect hose (1) to pressure switch (2) and elbow (3).ERemove elbow (8) from nipple (9).TA58090 16-39/(16-40 blank)Change 2TM 9-2350-267-20