14-68.2Change 4TM 9-2350-267-20PERSONNEL HEATER: REMOVAL AND INSTALLATIONREMOVALA Remove fire extinguisher mountings #1 and #2 (p 14-30).B Disconnect electrical connector (1).NOTEIf hoses in steps C and D cannot be removed frompersonnel heater, disconnect hoses at other end.C Loosen clamp (2) and disconnect hose (3).D Loosen clamp (4). Disconnect hose (5).NOTEUse a suitable container to catch fuel that will drainfrom disconnected lines.EUnscrew nut (8) from elbow (9). Remove fuel line (10). Catch drainedfuel.FLoosen two clamps (11).G Remove personnel heater (12), loosen nut (6) and disconnect exhausttube (7).