ENGINE AFES DEACTIVATION/REACTIVATION FOR SAFE MAINTENANCE
INITIAL SETUP
General Safety Instructions:
Test Equipment/Special Tools:
Wrench, adjustable 15 (item 67, Appx B)
Personnel Required:
Two
References:
TM 9-2350-267-10
Any AFES in need of maintenance or repair is more prone to
accidental discharge. Accidental discharge could lead to frostbite or
other injury. Small parts or tools become dangerous projectiles
when propelled by Halon discharging at 750 psi.
Do not strike cylinder bottles with tools. Do not drop cylinder bot-
tles. Be careful when handling cylinder bottles to prevent acciden-
tal discharge.
DEACTIVATION
WARNING
AFES is designed to provide 2 to 4 hours of fire
protection AFTER vehicle shutdown. Turning
MASTER switch OFF does NOT deactivate
AFES. Working on AFES when active may
cause serious injury to personnel.
A
Turn Maintenance switch (1) on engine T/A panel (2 or 3) to
vertical position. Make sure all lights, including POWER
ON light (4), go off.
B
Move projectile racks to rear of vehicle (TM 9-2350-267-10).
14-14.3
Change 3
TM 9-2350-267-20