TROUBLESHOOTING - Continued
TM 9-2350-267-10
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
32.
33.
34.
35.
PROJECTILE RACKS
PROJECTILE DOES NOT GO INTO RACK TUBE
Step 1. Check inner diameter of tube for obstruction or damage.
Remove obstruction if possible. Notify Organizational Maintenance if tube is
damaged.
Step 2. Check locking shoe for locked position.
Open locking handles.
PROJECTILE(S) ARE NOT HELD IMMOBILE IN TUBE
Step 1.
Step 2.
Check that handles are in locked position.
Place handles in locked position.
Check for defective lock. If damaged, notify Organizational Maintenance.
PROJECTILES WILL NOT COME OUT OF TUBE(S)
Step 1. Make sure rack is unlocked and handles are positioned up (released).
Step 2. Remove projectiles by pulling on nose plug with cargo hook.
Notify Organizational Maintenance.
VENTILATED FACE PIECE SYSTEM
REDUCED OR NO AIR FLOW TO VENTILATED FACE PIECE
Step 1. Check vehicle MASTER switch.
Turn MASTER switch ON.
3-17