TM 9-2350-267-10
TROUBLESHOOTING - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
STACKER - Continued
Step 2. Check flow control valve setting.
Turn flow control valve knob clockwise slowly until chain speed is satisfac-
tory.
30. STACKER TRAY MOVES SLOWLY OR ERRATICALLY
Step 1.
Step 2.
Step 3.
Check flow control valve setting.
Turn flow control valve knob clockwise slowly until chain speed is satisfac-
tory.
Check main hydraulic pressure gage for reading of 100 to 300 psi.
Notify Organizational Maintenance if pressure is not within range.
Check chain tension.
Adjust chain tension (p 3-44).
31. MANUAL WINCH WILL NOT OPERATE
Step 1.
Step 2.
Step 3.
Check that cable is properly routed over pulley.
Rethread cable.
Check that tray carrier is disconnected from chain.
Remove bolts that connect carrier to chain.
Check that cable is properly connected to tray carrier.
Attach cable clevis.
3-16