TM 9-2350-267-10HYDRAULIC RESERVOIR - holds hydraulic system fluid. Reservoir capacity is 13 gallons(49.26 L).SUCTION LINE - passes fluid to the main or backup hydraulic pump. A strainer at the inletof the line prevents contaminants from entering the hydraulic circuits.BALL VALVE - controls flow of hydraulic fluid through the suction line. This valve ismanually operated and must be opened before main or backup pump is operated.RETURN LINE - passes exhausted hydraulic fluid back to the reservoir. An in-line,10-micron filter removes particles from the returning fluid.BREATHER CAP - vents reservoir pressure to atmosphere.FILLER CAP AND TUBE - permit ease of hydraulic fluid refill. A strainer is housed withinthe tube to prevent entry of contaminants.NOTEHydraulic reservoir sight gage is only found on vehicles 1-344.Vehicles 345 and above do not have this gage.FLUID LEVEL TRANSMITTER - monitors the level of hydraulic fluid in the reservoir. Thetransmitter emits an electronic signal to a level gage on the hydraulic control panel.FLUID TEMPERATURE TRANSMITTER - monitors the temperature of hydraulic fluid inthe reservoir. The transmitter emits an electronic signal to a temperature gage on thehydraulic control panel.1-12