TM 9-2350-261-341. Measure resistance between pins on plug P105 (1) ofcable W118 and pins on connector J101 (2) ofEXTERNAL COMMUNICATION BOX A11 (3) frontpanel as follows:Pin 1 to pin 1A Pin 19 to pin 10A Pin 36 to pin 18BPin 2 to pin 1B Pin 20 to pin 10B Pin 37 to pin 19APin 3 to pin 2A Pin 21 to pin 11A Pin 38 to pin 19BPin 4 to pin 2B Pin 22 to pin 11B Pin 39 to pin 20APin 5 to pin 3A Pin 23 to pin 12A Pin 40 to pin 20BPin 6 to pin 3B Pin 24 to pin 12B Pin 41 to pin 21APin 7 to pin 4A Pin 25 to pin 13A Pin 42 to pin 21BPin 8 to pin 4B Pin 26 to pin 13B Pin 43 to pin 22APin 9 to pin 5A Pin 27 to pin 14A Pin 44 to pin 22BPin 10 to pin 5B Pin 28 to pin 14B Pin 45 to pin 23APin 11 to pin 6A Pin 29 to pin 15A Pin 46 to pin 23BPin 12 to pin 6B Pin 30 to pin 15B Pin 47 to pin 24APin 13 to pin 7A Pin 31 to pin 16A Pin 48 to pin 24BPin 14 to pin 7B Pin 32 to pin 16B Pin 49 to pin 25APin 15 to pin 8A Pin 33 to pin 17A Pin 50 to pin 25BPin 16 to pin 8B Pin 34 to pin 17B Pin 51 to pin 26APin 17 to pin 9A Pin 35 to pin 18A Pin 52 to pin 26BPin 18 to pin 9B3. Does multimeter read 0 ohms for each measurement?1. Replace cable W118(page 6-130).2. Verify no faults found.GO TO NEXT PAGEChange 32.1-31