TM 9-2350-261-34 V E H I C L E B A T T E R I E S D I S C H A R G E W I T H E X T E R N A L A C P O W E R A P P L I E DINITIAL SETUP Tools:General Mechanic’s Tool Kit (Item 35, App B)Digital multimeter (Item 62, App B)Fabricated Tool (page 2-4 Sec III f(1))Personnel Required:Power-Generation Equipment Repairer 52D10Helper (H)References:See your –10See your -20References (cont):TM 11-7010-256-12&PSee M1068 wiring diagram(see your -20, FO -9 thru -11)Equipment Conditions:Power control enclosure removed(see your -20)Power control enclosure power supply coverremoved (see your -20)Unit Level troubleshooting completed(see your -20)WARNINGHIGH VOLTAGE is used intheo p e r a t i o n o fthisequipment.DEATH ON CONTACT mayresult if personnel fail toobserve safety precautions.NEVER work on equipment unless atleast one other person familiar with theoperation and hazards of the equipmentis nearby. That person should also befamiliar with giving first aid. When anoperator helps a mechanic, that operatormust be warned about dangerous areas.SHUT OFF POWER supply to equipmentbefore beginning work. Make sure allexternal power is off/disconnected.BE CAREFUL not to contact high-voltageconnections when installing or operatingthis equipment.G O T O N E X T P A G EChange 32.1-9