TM 9-2350-261-20-4
REPLACE CHEMICAL AGENT WIRING HARNESS (M113A2 ONLY) -- Continued
0776 00
INSTALLATION
1.
Connect main harness (1) to distribution box (2).
2.
Secure main harness (1) to cradle (3) with clip (4).
3.
Slide new locknut (5), new lockwasher (6), washer (7), and new bushing (8) on main harness (1).
4.
Insert main harness (1) and bushing (8) through top.
5.
Install washer insulator (9) washer (10), new lockwasher (11), and new locknut (12) on main harness (1) and bushing (8).
6.
Install rubber bushing (13), packing (14), spring washer (15), and coupling nut (16) on main harness (1) and bushing (8).
7.
Tighten locknut (5).
8.
Install four shells (17) and slotted washers (18) on leads (19) and contacts (20).
9.
Connect four leads (19) of main harness (1) to four leads (21) of extension harness (22).
10. Install extension harness (22) on detector bracket (23) with four screws (24) and nuts (25).
11. Install detector bracket (23) on hull with four screws (26) and washers (27).
FOLLOW-THROUGH STEPS
1.
Connect battery ground lead (WP 0294 00).
END OF TASK