TM 9-2350-261-20-4
REPLACE CABLE W35, CABLE W28, AND CABLE ADAPTER
(M1068 ONLY)
THIS WORK PACKAGE COVERS:
INITIAL SETUP:
Personnel Required
Maintenance Level
Power-Generation Equipment Repairer 52D10
Unit
Equipment Condition
Tools and Special Tools
Engine stopped (see your -10)
Carrier blocked (see your -10)
Materials/Parts
All external power disconnected (TM 11-7010-256-
Tie strap (5)
12&P)
Battery ground lead disconnected (WP 0294 00)
REMOVAL
1.
Disconnect cable plug W28 P1 (1) from connector adapter plug T1 P1 (2).
2.
Disconnect cable plug W28 P2 (3) from circuit 38B lead (4).
3.
Disconnect cable plug W35 P9 (5) from power control enclosure jack A1 J29 (6).
4.
Disconnect cable plug W35 P1 (7) from connector adapter plug T1 P2 (8).
5.
Remove five tie straps (9) and cable W35 from carrier. Discard tie straps.
6.
Disconnect circuit 38B lead (10) from connector adapter plug T1 P3 (11).