TM 9-2350-261-20-4
REPLACE POWER CONTROL ENCLOSURE AC AND DC METERS AND LIGHT
0729 00
INDICATORS (M1068 ONLY) -- Continued
NOTE
Tag all leads before removing them.
3.
Remove two nuts (1) and washers (2) from meter M1 (3).
4.
Remove two nuts (1) and washers (2) from meter M2 (4).
5.
Remove circuits 29A lead (5) and 30A lead (6) from meter M1 (3).
6.
Remove circuits 31F lead (7), 32F lead (8), and 28C lead (9) from meter M2 (4).
7.
Remove three screws (10), locknuts (11), and meter M1 (3) from faceplate (12). Discard locknuts.
8.
Remove three screws (10), locknuts (11), and meter M2 (4) from faceplate (12). Discard locknuts.
9.
Remove two jamnuts (13) and lockwashers (14) from two indicator lights (15). Remove lights from faceplate (12).
10. If necessary, remove lens (16) and bulb (17) from indicator light (15).
0729 00-2