TM 9-2350-261-20-4
REPLACE SMOKE GENERATOR ASSEMBLY AND SUPPORT BRACKET
0697 00
(M1059 ONLY) -- Continued
INSTALLATION
Position generator support bracket (8) on hull top. Secure with four screws (6) and new lockwashers (7). TIGHTEN
1.
SCREWS TO 54-59 LB-FT (73-80 NM) TORQUE. Use torque wrench.
WARNING
Hanging loads, heavy parts, and overhead equipment can fall unexpectedly and kill or injure
you.
Stay clear of hanging loads, heavy parts, and overhead equipment. Use correct lifting devices.
Always have helper guide heavy parts and equipment.
Using a suitable lifting device, install smoke generator on armor shield.
2.
Connect glow plug cable (19) to preheat harness jack (20) to panel (21) on smoke generator.
3.
Connect fuel supply hose (5) to fuel supply connector (22) and fuel return hose (24) to fuel return connector (23).
4.
Connect fog oil hose (9) to cover assembly connector (10).
5.
Connect air hose (11) to cover assembly connector (12).
6.
Connect electrical cable assembly (13) to cover connector 5J1 (14).
7.
Slide generator onto support bracket (4). Have helper assist.
8.
Secure generator to support (4) with two screws (15), wedges (16), four washers (17), and two new locknuts (18).
9.