TM 9-2350-261-20-4
REPLACE M14 NBC HOSES AND BRACKETS (M113A2 AMBULANCE
0688 00
ONLY) -- Continued
INSTALLATION
1.
Install clamp (14) on hose assembly (4). Secure clamp to top plate with screw (12) and new lockwasher (13).
2.
Install hose assembly (4) on air purifier (11).
3.
Install bracket (9), two screws (7), and washers (8) on top plate.
4.
Install six clips (2), screws (5), and new lockwashers (6) on top plate.
5.
Install two hoses (1) on Y-connector (3) of hose assembly (4).
6.
Route two hoses (1) around bracket (9), and insert in six clips (2).