TM 9-2350-261-20-4
REPLACE M3 NBC FILTER SWITCH AND MOUNT BRACKET (M577A2
0674 00
ONLY) -- Continued
INSTALLATION
1.
Install circuit 579A (1) and grommet (2) through frame (3).
Install three clamps (4), screws (5), and new lockwashers (6) on circuit 579A (1).
2.
3.
Install five new tie straps (7) on circuit 579A (1).
4.
Connect circuit 597A (1) to connector (8) on instrument panel (9).
Install bracket (10), ground lead (11), two screws (12), four washers (13), and two new locknuts (14) on frame (3).
5.
Install switch assembly (15), two screws (16), four washers (17), and two new locknuts (18) on bracket (10).
6.
Connect circuit 579A (1) to circuit breaker (19) on switch assembly (15) and connector (8) at instrument panel (9).
7.
Connect circuit 537B (20) and ground lead (11) to light (21) on switch assembly (15).
8.
FOLLOW-THROUGH STEPS
1.
Connect battery ground lead (WP 0294 00).
2.
Install instrument panel (WP 0238 00).
END OF TASK